WhatsApp
HG Walls India Pvt Ltd provides project-specific façade and glazing solutions from Chennai.
+91- 97909 44004

Skylights and Atrium Glass Roofs

Skylights and atrium glass roofs with project-specific framing, slopes, joints and drainage.

Browse All Products & Services
Engineered atrium skylight and glass roof installed by HG Walls
Project-specific skylight or atrium roof with coordinated framing, drainage and overhead glazing.

Technical Description

Skylights and atrium roofs introduce daylight through overhead glazed assemblies that may be flat, sloped, pyramid-shaped, ridge-and-valley, barrel/dome-like or custom geometric forms. Supporting structures may use aluminium rafters, pressure-capped systems, structural steel grids or point-fixed arrangements. Successful performance depends on managing water, condensation, thermal movement and overhead-glazing safety.

HG Walls is based in Chennai and provides skylights and atrium glass roofs for suitable projects across Tamil Nadu, South India and other locations in India, subject to project scope, programme, logistics and commercial feasibility.

System Composition & Configuration

  • Laminated/heat-treated overhead glazing, solar-control glass or DGU where required.
  • Aluminium rafters/transoms, pressure plates/caps or structural steel support grids.
  • Gaskets, setting blocks, sealants, drainage channels, gutters, flashings and kerbs.
  • Anchors, support brackets, expansion joints and safe-access/maintenance provisions.

Engineering & Performance Considerations

The roof geometry should provide positive drainage and avoid ponding at glass joints, valleys or perimeter gutters. Design must account for wind pressure/uplift, glass self-weight, support deflection, thermal expansion, solar heat gain, internal condensation, drainage capacity and post-breakage safety. DGU or coated glass requires correct orientation and edge-seal compatibility. Perimeter kerbs and flashings should integrate with the main roof waterproofing. Long runs require movement joints and controlled mullion/rafter splices. Maintenance access and cleaning load considerations should be addressed where relevant.

Key Design Inputs

  • Roof geometry, minimum drainage slope, valleys/gutters and emergency overflow strategy where required.
  • Overhead safety glass/DGU make-up, wind uplift, support deflection, solar/thermal and condensation conditions.
  • Movement joints, rafter/transom drainage, perimeter kerb/roof-waterproofing and maintenance access.

HG Walls Scope / Execution Controls

HG Walls provides design coordination, support-frame fabrication, glass/aluminium detailing, gutters and flashing interfaces, glazing, pressure caps or point fittings, sealants, installation and testing support. Site QA should inspect slope, gutter continuity, weep paths, glass clearances, cap/gasket continuity and perimeter waterproofing interfaces.

QA / Site Acceptance Checks

  • Rafter/transom line and level, gasket/cap continuity, setting blocks and glass edge clearances.
  • Gutter, weep and drainage-path inspection before closure; perimeter flashing integration check.
  • Controlled water testing where specified and completion of safe-access/maintenance provisions.

Typical Applications

Malls, hotels, offices, residences, courtyards, atriums and institutional buildings.

Technical Note

The system must be engineered for project-specific air and water performance; drainage, seals, interfaces, workmanship and testing govern the achieved result.

Discuss your project with HG Walls

Discuss Your Project With HG Walls

Share the roof geometry, spans, slope, drainage layout and performance requirement for a skylight review.