Technical Description

A unitized curtain wall is formed from factory-assembled façade panels that generally combine aluminium framing, vision glass, spandrel glass or opaque infill, gaskets, pressure-equalised cavities and interlocking perimeter joints. The completed units are glazed, sealed, inspected and labelled in a controlled fabrication environment and then transported to site for fixing to pre-installed floor-edge anchors. The approach is particularly suited to high-rise and repetitive façades where rapid enclosure, systematic factory QA and controlled panel sequencing are important.

HG Walls is based in Chennai and provides unitized curtain wall systems for suitable projects across Tamil Nadu, South India and other locations in India, subject to project scope, programme, logistics and commercial feasibility.

System Composition & Configuration

  • Male/female stack-joint aluminium profiles, mullion/transom members, corner units and perimeter closure profiles.
  • Vision/spandrel glass, opaque panels, shadow boxes or insulated back pans as required by the approved façade build-up.
  • EPDM or compatible gaskets, seals, internal air seals, external rain barriers and controlled drainage chambers.
  • Floor-edge anchors, cast-in/chemical fasteners where approved, brackets, setting components, fire-stop interfaces and perimeter closures.

Engineering & Performance Considerations

Unitized performance depends on joint geometry and movement capacity as much as member strength. Stack joints should accommodate fabrication and slab-edge tolerances, thermal movement, inter-storey drift, differential shortening and installation variation without disengaging gaskets or blocking drainage. The façade should be checked for wind pressure/suction, panel and mullion deflection, anchor forces, glass support, air leakage, static/dynamic water penetration, thermal bridging, acoustic requirements and spandrel/fire interfaces. Corner panels, parapets, podium transitions and starter/sill units require special drainage and closure detailing. Performance mock-up and chamber testing requirements should be defined early because they can affect tooling, gaskets, seal configuration and programme.

Key Design Inputs

  • Floor-to-floor height, slab-edge geometry, anchor zone, panel module and maximum transport/lifting size.
  • Specified inter-storey drift, thermal movement, slab deflection/shortening and permitted installation tolerances.
  • Air/water/structural performance, spandrel/fire-stop build-up, acoustic/thermal requirements and PMU strategy.

HG Walls Scope / Execution Controls

HG Walls coordinates system detailing, unit sizes, anchors and embeds, slab-edge surveys, fabrication drawings, machining, frame assembly, glazing, gasket/seal installation, unit labelling, packing, transportation, lifting strategy, installation sequence, alignment, perimeter closures and testing. Factory inspection should control diagonal dimensions, joint geometry, seal continuity, drainage openings and glass support; site QA should control anchor positions, panel level/plumb, stack engagement and perimeter interfaces.

QA / Site Acceptance Checks

  • Factory unit squareness/diagonal checks, gasket engagement, seals, drainage openings and panel identification.
  • Anchor survey, embed/fastener verification, stack-joint engagement, unit level/plumb and perimeter closure checks.
  • Mock-up test observations, rectification controls, packing protection and damage inspection after installation.

Typical Applications

High-rise offices, hotels, IT parks, residential towers, institutional buildings and large repetitive façades.